Part Number Hot Search : 
354HF7 R5F7286 80C55 2SC5739 2SC17 AT24C OPA256C1 FFCKS5S2
Product Description
Full Text Search
 

To Download SSR0340-4 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 SSR0340-4
SOLID STATE DEVICES, INC.
14830 Valley View Blvd * La Mirada, Ca 90638 Phone: (562) 404-7855 * Fax: (562) 404-1773 ssdi@ssdi-power.com * www.ssdi-power.com
Designer's Data Sheet
FEATURES:
* * * * * * * Low Forward Voltage Drop: 0.48V Hermetically Sealed Surface Mount Package Guard Ring for Overvoltage Protection Eutectic Die Attach TX, TXV and Space Level Screening Available 3 Amp Replacement for 1N5817, 1N5818, and 1N5819 Higher Voltages Available; Contact Factory
3 AMP 40 VOLTS SCHOTTKY SMD RECTIFIER
LCC4
Maximum Ratings
Peak Repetitive Reverse and DC Blocking Voltage Average Rectified Forward Current (Resistive Load, 60Hz, Sine Wave, TA = 100oC) Peak Surge Current (8.3 ms Pulse, Half Sine Wave Superimposed on Io, allow junction to reach equilibrium between pulses, TA = 25oC) Operating and Storage Temperature Maximum Thermal Resistance Junction to Case
SYMBOL VRRM VRWM VR Io
VALUE 40 3
UNITS Volts Amps
IFSM Top & Tstg R2JC
60 -55 TO +150 15
Amps
o
C
o
C/W
NOTE: All specifications are subject to change without notification. SCD's for these devices should be reviewed by SSDI prior to release.
DATA SHEET #:
SH0027A
SSR0340-4
SOLID STATE DEVICES, INC.
14830 Valley View Blvd * La Mirada, Ca 90638 Phone: (562) 404-7855 * Fax: (562) 404-1773 ssdi@ssdi-power.com * www.ssdi-power.com
Electrical Characteristics
Instantaneous Forward Voltage Drop (TA = 25oC, 300 :s Pulse) Instantaneous Forward Voltage Drop (TA = -55oC, 300 :s Pulse) Instantaneous Forward Voltage Drop (TA = +100oC, 300 :s Pulse) Reverse Leakage Current (Rated VR , 300 :sec pulse minimum) Junction Capacitance (VR = 5VDC, TA = 25oC, f = 1MHz) CASE OUTLINE: LCC4 PIN 1: Cathode PIN 2: Anode PIN 3: Anode PIN 4: Cathode IF = 1ADC IF = 2ADC IF = 3ADC IF = 1ADC IF = 2ADC IF = 3ADC IF = 1ADC IF = 2ADC IF = 3ADC TA = 25oC TA = +100oC
SYMBOL VF1 VF2 VF3 VF4 VF5 VF6 VF7 VF8 VF9 IR1 IR2 CJ
MAXIMUM 0.48 0.58 0.71 0.56 0.64 0.74 0.40 0.53 0.66 0.1 10 300
UNITS VDC
VDC
VDC mA pF
TYPICAL OPERATING CURVES
(TA = 25oC unless otherwise specified)
PERCENT OF MAXIMUM FORWARD CURRENT RATING (%)
118oC
100 80 60 40 20 0 0 25 50 75 100 125 150 175
CASE TEMPERATURE (oC)


▲Up To Search▲   

 
Price & Availability of SSR0340-4

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X